Espressif Systems /ESP32-P4 /PCNT /U0_STATUS

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as U0_STATUS

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0CNT_THR_ZERO_MODE_U 0 (CNT_THR_THRES1_LAT_U)CNT_THR_THRES1_LAT_U 0 (CNT_THR_THRES0_LAT_U)CNT_THR_THRES0_LAT_U 0 (CNT_THR_L_LIM_LAT_U)CNT_THR_L_LIM_LAT_U 0 (CNT_THR_H_LIM_LAT_U)CNT_THR_H_LIM_LAT_U 0 (CNT_THR_ZERO_LAT_U)CNT_THR_ZERO_LAT_U

Description

PNCT UNIT0 status register

Fields

CNT_THR_ZERO_MODE_U

The pulse counter status of PCNT_U%s corresponding to 0. 0: pulse counter decreases from positive to 0. 1: pulse counter increases from negative to 0. 2: pulse counter is negative. 3: pulse counter is positive.

CNT_THR_THRES1_LAT_U

The latched value of thres1 event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to thres1 and thres1 event is valid. 0: others

CNT_THR_THRES0_LAT_U

The latched value of thres0 event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to thres0 and thres0 event is valid. 0: others

CNT_THR_L_LIM_LAT_U

The latched value of low limit event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to thr_l_lim and low limit event is valid. 0: others

CNT_THR_H_LIM_LAT_U

The latched value of high limit event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to thr_h_lim and high limit event is valid. 0: others

CNT_THR_ZERO_LAT_U

The latched value of zero threshold event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to 0 and zero threshold event is valid. 0: others

Links

() ()